Skip to main content Skip to search Skip to main navigation
Menu

Accessories for Gas Warining Device X-am® 7000

Description
This device is the innovative solution for the simultaneous and continuous detection of up to five gases. A combination of more than 25 sensors allows flexible solutions to individual monitoring tasks. The device can be equipped with three electrochemical, and two catalytic bead, infrared or photoionisation sensors. It is the ideal companion in a great number of applications where reliable monitoring of oxygen, toxic and combustible gases and vapors in ambient air is necessary.

Basic unit with rubber-boot, carrying strap, calibration adapter, water and dust filter. In order to get a fully operational unit, a power pack and up to 5 sensors have to be ordered. And, optionally, a built-in pump or a datalogger can be ordered.


Specifications
Temperature: Pressure: Humidity:
-20 ... +55 °C, short-term -40 ... +60 °C 700 ... 1300 hPa 10 ... 95 % r.F.
Alarms (visual/audible):
360° flashing LEDs / 100 dB(A) at 30 cm
Charging time:
3.5 to 7 hours, depending on battery type
Pump mode:
maximum hose length of 45 m
Dimensions (W x H x D):
150 x 140 x 75 mm
Weight (basic unit/battery):
600 g / 490 g (3,0 Ah), 730 g (6,0 Ah)
Ingress protection:
IP 67
Approvals:
ATEX, MED, CSA, IECEx
Properties
Manufacturer Article Number: 8318607
Type: Set pump membrane
Skip product gallery

Other customers also bought

Analox Ltd.

Analox Ltd.
Carbon Dioxide Safety Monitor AX60
Gas warning device for precise measurement of the amount of CO2 in the air. 3 alarm settings factory set: Time-weighted average (TWA) alarm (5000 ppm; 0.5% CO2), Low alarm (15,000 ppm; 1.5% CO2) and High alarm (30,000 ppm; 3% CO2)No calibration required (unless local regulations state otherwise)Very long life sensor can last up to 15 yearsUp to 4 x CO2sensors and 8 x CO2 alarms can be used per Central Display UnitSupplied with a relay on each alarm which can be used to trigger ventilation, extraction or a building management systemEasy installation and maintenance can be conducted by the userAdditional (quick connect) CO2 sensors and alarms available if more than one entrance to the laboratory or more than one risk areaAssists in compliance with Exposure Limit regulations such as EH40Scope of delivery: wall-mounted central display unit, CO2 sensor and CO2 alarm which can provide an early warning of a CO2 leak.Specifications:Range : Accuracy :0.1 to 5 % CO2 +/- 5 % of alarm setpointAlarm intensity :88 dbAMonitor Display :16 digit 2 line LCD in ppmTWA Alarm :5,000 ppm (0.5 %) over 8 hoursCO2 Alarms :15,000 ppm (1.5 %) and 30,000 ppm (3 %)Operating Temperature :-5 to 50 °CCentral Unit Dimensions :175 x 110 x 75 mmSensor & Alarm Dimensions :72 x 170 x 45 mmIP Rating :IP55 (IP54 Central Display Unit)Warranty :5 years for electronics and sensor
From €48.90*
Skip product gallery

Similar products

Dräger-Tubes®
The Dräger-Tubes® measuring system is the safe method for measuring pollutants in the soil, water and air. More than 500 substances can be measured in varying concentrations. The long-established principle of Dräger-Tubes® is still the same. A defined volume of gas/air must be pumped through the sampling tube. This can be achieved by using the Accuro® gas pump. On contact with the substance under test the reagent system contained in the tube reacts and displays a colour. The strength of the concentration of the substance is shown by the length of the colour band displayed and can be read directly from the scale. The Dräger-Tubes® sampling system provides accuracy, efficiency, quick and easy handling. Over 250 tubes are available on request for all substances and measuring fields. Further sampling devices, diffusion tubes for long-term measurements as well as sampling systems with activated carbon tubes, ORSA collector and TDS thermodesorption tubes are also available.
From €73.50*

Dräger-Tubes®
The Dräger-Tubes® measuring system is the safe method for measuring pollutants in the soil, water and air. More than 500 substances can be measured in varying concentrations. The long-established principle of Dräger-Tubes® is still the same. A defined volume of gas/air must be pumped through the sampling tube. This can be achieved by using the Accuro® gas pump. On contact with the substance under test the reagent system contained in the tube reacts and displays a colour. The strength of the concentration of the substance is shown by the length of the colour band displayed and can be read directly from the scale. The Dräger-Tubes® sampling system provides accuracy, efficiency, quick and easy handling. Over 250 tubes are available on request for all substances and measuring fields. Further sampling devices, diffusion tubes for long-term measurements as well as sampling systems with activated carbon tubes, ORSA collector and TDS thermodesorption tubes are also available.
From €73.00*

Gas sampling tubes, DURAN® tubing
Gas sampling tubes, with two one-way stopcocks NS 14 (with retaining device), connections: capillary tube (outer dia. 8 mm, inner dia. 2,7 mm), glass olive (outer dia. 9 mm), with inscription label.
From €83.30*

Gas sampling tubes, DURAN® tubing, with nozzle
Gas sampling tubes, with nozzle (with thread GL14 and septa), with two one-way stopcocks NS14 (with retaining device), connections: capillary tube (outer dia. 8 mm, inner dia. 2.7 mm), glass olive (outer dia. 9 mm), with inscription label.
From €98.80*

Gas Pump accuro®
Fast measurement with one hand: The Dräger-Tube pump accuro® allows you to use the established Dräger-Tubes® to take measurements under extreme conditions. The easy-to-use Dräger-Tubes have already been calibrated and form a perfect unit with the Dräger-Tube pump.Fast measurement with one hand: The Dräger-Tube pump accuro® allows you to use the established Dräger-Tubes® to take measurements under extreme conditions. The easy-to-use Dräger-Tubes have already been calibrated and form a perfect unit with the Dräger-Tube pump.
From €450.00*

Dräger-Tubes ®
The Dräger-Tubes® measuring system is the safe method for measuring pollutants in the soil, water and air. More than 500 substances can be measured in varying concentrations. The long-established principle of Dräger-Tubes® is still the same. A defined volume of gas/air must be pumped through the sampling tube. This can be achieved by using the Accuro® gas pump. On contact with the substance under test the reagent system contained in the tube reacts and displays a colour. The strength of the concentration of the substance is shown by the length of the colour band displayed and can be read directly from the scale. The Dräger-Tubes® sampling system provides accuracy, efficiency, quick and easy handling. Over 250 tubes are available on request for all substances and measuring fields. Further sampling devices, diffusion tubes for long-term measurements as well as sampling systems with activated carbon tubes, ORSA collector and TDS thermodesorption tubes are also available.
From €71.50*

Gas Pump accuro® set
Fast measurement with one hand: The Dräger-Tube pump accuro® allows you to use the established Dräger-Tubes® to take measurements under extreme conditions. The easy-to-use Dräger-Tubes have already been calibrated and form a perfect unit with the Dräger-Tube pump.Gas pump Dräger accuro® set consisting of:Dräger-Tubes® pump accuro®, ready bag, with tube opener and spare part set
From €550.00*
New

Gassammelrohre, PP, mit geradem Absperrhahn an beiden Enden
Absperrhähne, PP, mit frei drehbaren PTFE-Stopfen. Die Enden sind für Schläuche mit einem Innendurchmesser von 6,4 bis 9,5 mm geeignet.Absperrhähne, PP, mit frei drehbaren PTFE-Stopfen. Die Enden sind für Schläuche mit einem Innendurchmesser von 6,4 bis 9,5 mm geeignet.
From €1,433.90*

Gas sampling tubes, PP, with one straight bore stopcock and one screw fitting
Stopcocks, PP, with free-turning PTFE plugs. Ends accept 6.4 to 9.5 mm I.D. tubing.Screw fitting with silicone rubber septum, 6 septa included.
From €1,637.50*

Gas analyzers MAT1400/MAT1500
Gas analyzers MAT1000 series are used for measuring oxygen concentrations (O2) or optional carbon dioxide concentrations (CO2).Applies to all models of MAT1000 series:Easy and intuitive operation via touchscreen, even by untrained personnelCreate your own methodAvailable method parameters: scales, measurement procedures, limit values, comment and much moreSelectable measurement methods: single or continuousSeveral single measurement procedures: manual, automatic, min/max detectionShortcut keys for most important functionsShort measurement period, high accuracy even with small sample volumeValidation possibleCompliance with global standards such as GMP/GLP and 21 CFR Part 11Documentation of all measured values of the last 999 measurementsIntegrated interfaces, flexible data export (USB, Ethernet, RS-232)Compact design in robust cast aluminum housingBuilt-in air pressure sensorIntegrated flow rate monitoringGas analysers for controlling protective gas packaging. The MAT1400 equipped with a zirconium dioxide sensor (ZrO2) measures the oxygen concentration over the entire measurement range between 0 and 100 vol% and with an excellent accuracy of ±0.001 vol%. The MAT1500 additionally features a non-dispersive infrared sensor for measuring carbon dioxide within the range of 0 and 50 vol% and with a high accuracy of ±0.5 vol%. Both devices are suitable for the random sampling as well as the permanent monitoring of the gas mixture used on packaging machines. Their solid metal housing with an interchangeable protective cover offers protection against impact and dirt from the outside.Measurement of O2 and CO2 e.g. in modified atmosphere packaging, for work with modified atmosphere conditions.For high sample throughputFor high O2 concentrationHigh precision with the lowest O2 concentrationsWide measurement rangeDrift-free zirconia sensor (ZrO2)Low-drift non-dispersive infrared sensor (NDIR), model MAT1500Environmental compensated CO2 measurement, model MAT1500SpecificationsO2 measuring range:0 to 100 Vol.-%Accuracy:0.001 Vol.-% (1 Vol.-%) 0.1 Vol.-% (6 Vol.-%) 0.1 Vol.-% (35 Vol.-%)Resolution: CO2 measuring range (only MAT1500):0.001 Vol.-% 0 to 50 Vol.-%Accuracy: Resolution:±0.5 Vol.-% 0.1 Vol.-%Average measurement period: Heating time:5 to 10 sec 10 minInterface:RS-232, USB, EthernetDimensions (W x D x H):200 x 350 x 150 mmWeight:4.6 kgPower consumption:60 WPower supply:100-250 V, 50/60 Hz
From €7,139.00*

Carbon Dioxide Safety Monitor AX60
Gas warning device for precise measurement of the amount of CO2 in the air. 3 alarm settings factory set: Time-weighted average (TWA) alarm (5000 ppm; 0.5% CO2), Low alarm (15,000 ppm; 1.5% CO2) and High alarm (30,000 ppm; 3% CO2)No calibration required (unless local regulations state otherwise)Very long life sensor can last up to 15 yearsUp to 4 x CO2sensors and 8 x CO2 alarms can be used per Central Display UnitSupplied with a relay on each alarm which can be used to trigger ventilation, extraction or a building management systemEasy installation and maintenance can be conducted by the userAdditional (quick connect) CO2 sensors and alarms available if more than one entrance to the laboratory or more than one risk areaAssists in compliance with Exposure Limit regulations such as EH40Scope of delivery: wall-mounted central display unit, CO2 sensor and CO2 alarm which can provide an early warning of a CO2 leak.Specifications:Range : Accuracy :0.1 to 5 % CO2 +/- 5 % of alarm setpointAlarm intensity :88 dbAMonitor Display :16 digit 2 line LCD in ppmTWA Alarm :5,000 ppm (0.5 %) over 8 hoursCO2 Alarms :15,000 ppm (1.5 %) and 30,000 ppm (3 %)Operating Temperature :-5 to 50 °CCentral Unit Dimensions :175 x 110 x 75 mmSensor & Alarm Dimensions :72 x 170 x 45 mmIP Rating :IP55 (IP54 Central Display Unit)Warranty :5 years for electronics and sensor
From €48.90*